logo
Telefon:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

Service Gruppe der China-Welttechnologie-medizinischen Ausrüstung

Mit Gewinn für beide Parteien zusammen!

Startseite ProduktePatientenmonitor-Teile

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment

  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
Produktdetails:
Markenname: Edan
Modellnummer: F300
Zahlung und Versand AGB:
Min Bestellmenge: 1
Lieferzeit: 3-5 Werktage
Zahlungsbedingungen: T/T, Western Union, Paypal
Kontakt
Ausführliche Produkt-Beschreibung
Teilenummer: E204460 Kompatibles Gerät: F300
Ausgabetyp: Quadratur (A/B-Phase) digital Betriebsspannung: 5V DC
Rotationsleben: ≥ 1,000,000 Zyklen Verbindung: Kodierter Stiftleistenstecker
Vorteile: Schutzmonitor Garantie: 90 Tage
Material: Strukturierte ABS/PC-Mischung Betriebstemperatur: 0°C | 40°C

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment

 

Encoder Introduction

 

The encoder features a compact, precision-designed housing made of high-strength engineering plastic with a smooth, matte finish that seamlessly integrates with the display's front panel. At its core, the encoder utilizes optical or mechanical sensing technology to convert rotational motion into precise digital signals for parameter adjustment and menu navigation. A white interface on the top allows for precise docking with the device's mainboard. Internally, it contains high-resolution encoding elements that generate quadrature output signals, enabling the display mainboard to accurately detect the direction and amplitude of rotation. The encoder features integrated button functionality for both selection and confirmation. It uses a pin header with anti-misalignment features to prevent incorrect installation. This encoder assembly serves as the primary user interface for adjusting critical parameters such as alarm limits, volume control, and menu navigation during fetal monitoring.

 

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment 0

 

About Encoder

 

  • Precise Parameter Adjustment: Through rotation, it precisely controls the threshold adjustment of monitoring parameters such as fetal heart rate and uterine contractions, and switches menu options. Each rotation outputs a stable digital signal, ensuring adjustment accuracy.
  • Menu Navigation and Confirmation: Combined with the press function, it enables confirmation and return operations for menu options, simplifying the operation process for medical staff.
  • Stable Signal Transmission: It converts rotation and press actions into electrical signals and transmits them to the mainboard in real time, ensuring sensitive and delay-free device response.
  • Operation Feedback: Through an internal damping structure, it provides clear tactile feedback for rotation and press, allowing medical staff to intuitively perceive whether the operation is effective and avoid misoperation.

 

Troubleshooting

 

 

Cause

 

 

Troubleshooting and Solutions

1. Damaged internal encoder module

2. Poor contact or broken ribbon cable

3. Motherboard interface failure

 

1. Re-plug the ribbon cable and check if it is firmly plugged in.

2. Replace with a new encoder and test.

3. Check the motherboard connector for bent pins.

 

 

1. Encoder push switch damaged

2. Push mechanism stuck

3. Mainboard button detection circuit malfunction

 

1. Replace with a new encoder

2. Check for foreign objects obstructing the shaft

3. Troubleshoot the mainboard button detection circuit

 

Precautions

 

1. Anti-static: Wear anti-static gloves throughout operation to prevent static electricity from damaging the encoder or motherboard.

 

2. Handle with care: The encoder is a precision electronic component; avoid dropping, squeezing, or handling with excessive force.

 

3. Genuine parts: Always use genuine Mindray encoders (model E204460) to avoid compatibility issues.

 

4. Regular maintenance: Check the encoder's feel and response every 6-12 months and replace worn parts promptly.

Kontaktdaten
China World Technology Medical Equipment Service Group

Ansprechpartner: Rita

Telefon: +8618279091952

Senden Sie Ihre Anfrage direkt an uns
China World Technology Medical Equipment Service Group
TianHe-Bezirk, Guangzhou, Guangdong
Telefon:86-198-5481-5217
Mobile Seite Datenschutz-Bestimmungen | CHINA Gut Qualität Benutzter Patientenmonitor Lieferant. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.