logo
Telefon:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

Service Gruppe der China-Welttechnologie-medizinischen Ausrüstung

Mit Gewinn für beide Parteien zusammen!

Startseite ProduktePatientenmonitor-Teile

Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410

Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410

  • Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410
  • Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410
  • Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410
  • Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410
  • Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410
  • Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410
Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410
Produktdetails:
Markenname: Biolight
Modellnummer: M66
Zahlung und Versand AGB:
Min Bestellmenge: 1
Lieferzeit: 3-5 Werktage
Zahlungsbedingungen: T/T, Western Union, Paypal
Kontakt
Ausführliche Produkt-Beschreibung
Teilenummer: M0301025-0410 Kompatibles Gerät: M66
Material: Medizinisches PVC Oberflächenbeschaffenheit: Strukturierter Griff, glatt matt
Farbe: Blau Produkttyp: Kabel für medizinische Geräte
Steckertyp: Mehrpoliges Rundschreiben mit Schlüssel Abschirmung: Folie mit Beilaufdraht
Lagertemperatur: -20°C ~ 60°C Anwendung: Sauerstoffüberwachung

Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410

 

Main function:

 

This interface is the core hub of the Biolight M66 monitor's oxygen monitoring system: it precisely connects to the oxygen tubing and pulse oximeter probe via a blue gas path interface, establishing a sealed, leak-free gas path channel to ensure the accuracy of oxygen concentration acquisition; at the same time, it transmits the acquired oxygenation data to the host via a shielded cable, allowing medical staff to monitor key information such as the patient's blood oxygen and oxygen concentration in real time, and also preventing external dust and disinfectant from seeping in, protecting the internal gas path and circuit modules of the device from contamination.

 

Biolight M66 Patient Monitor Oxygen Interface Cable M0301025-0410 0

 

About the Interface

 

1. Component Structure: Blue snap-on pneumatic interface + shielded transmission cable + white connector terminals
2. Interface Material: Medical-grade high-strength corrosion-resistant engineering plastic (blue end)
3. Sealing Structure: Built-in medical-grade silicone gasket to ensure leak-free pneumatic path
4. Cable Characteristics: With anti-interference shielding layer to prevent signal attenuation and electromagnetic interference
5. Connection Method: Snap-on fixing at the pneumatic end, ribbon cable connector at the signal end to the motherboard

 

Installation and Removal Methods

 

Removal Steps:

 

1. Before operation, turn off the power to the Biolight M66 monitor, disconnect all external oxygen tubing, probes, and power cords, and place the device stably on the operating table.

2. Pinch the outside of the blue gas line connector, gently pull outwards and slowly rotate, using the springy clips to remove the connector from the slot on the device. Do not pry forcefully to avoid damaging the internal gas line connectors.

3. Locate the white connector at the end of the cable, pinch the spring clips on both sides of the connector, and gently pull it off (do not pull the cable directly to prevent pin breakage or cable damage). The old connector assembly can then be completely removed.

 

Installation Steps:

 

1. Take out the new M0301025-0410 oxygen connector. First, align the white terminal with the corresponding connector on the main board, insert it smoothly, and secure the spring clips, ensuring a firm and secure connection.

 

2. Align the blue gas line connector with the dedicated slot on the side of the device, pressing evenly and vertically until you hear a "click" sound. Gently pull the connector to confirm it is secure and does not detach.

 

3. Connect the oxygen tubing or pulse oximeter probe and check that the gas path is unobstructed and leak-free; turn on the power and confirm that the monitor can normally collect and display oxygen concentration and pulse oximetry data to complete the installation.

Kontaktdaten
China World Technology Medical Equipment Service Group

Ansprechpartner: Rita

Telefon: +8618279091952

Senden Sie Ihre Anfrage direkt an uns
China World Technology Medical Equipment Service Group
TianHe-Bezirk, Guangzhou, Guangdong
Telefon:86-198-5481-5217
Mobile Seite Datenschutz-Bestimmungen | CHINA Gut Qualität Benutzter Patientenmonitor Lieferant. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.