logo
Telefon:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

Service Gruppe der China-Welttechnologie-medizinischen Ausrüstung

Mit Gewinn für beide Parteien zusammen!

Startseite ProduktePatientenmonitor-Teile

Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516

Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516

  • Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516
  • Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516
  • Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516
  • Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516
  • Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516
  • Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516
Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516
Produktdetails:
Markenname: Comen
Modellnummer: C60
Zahlung und Versand AGB:
Min Bestellmenge: 1
Lieferzeit: 3-5 Werktage
Zahlungsbedingungen: T/T, Western Union, Paypal
Kontakt
Ausführliche Produkt-Beschreibung
Kompatibles Gerät: C60 Patientenüberwachung Schnittstellentyp: Masimo-kompatibel
Kabelmaterial: Medizinisches PVC Gemessene Parameter: SpO₂, Pulsfrequenz
Stromversorgung: 100-240 V AC, 50/60Hz Betriebstemperatur: 0°C bis 40°C
Typen von Patienten: Erwachsen, pädiatrisch Kabeltyp: Geschirmt, Mehrleiter
Steckertyp: Verriegelung (Monitor), Standard-Masimo (Sensor) Umfeld: Intensivstation, OP, Allgemeinstation
Hervorheben:

Comen C60 patient monitor cable

,

Massimo blood oxygen interface cable

,

patient monitor parts with warranty

Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516

 

Introduction

 

This product is a Masimo pulse oximetry interface cable (model: 36516), specifically designed for the C60 series patient monitors. It serves as a crucial connection between the Masimo pulse oximetry sensor and the main monitor, enabling accurate transmission of SpO₂ (oxygen saturation) and pulse rate data. One end of the component features a compact and durable connector for a robust friction-fit connection to the monitor's dedicated input port. The other end is a standard Masimo sensor connector, compatible with various reusable or disposable SpO₂ probes. The cable itself utilizes a flexible medical-grade PVC outer sheath and internal shielding layer to effectively prevent electromagnetic interference and signal attenuation.

 

Comen C60 Patient Monitor Massimo Blood Oxygen Interface Cable 36516 0

 

Main Functions

 

During blood oxygenation, the optical signal captured by the probe is transmitted intact through this cable to the Masimo processing module inside the monitor. After the signal is analyzed and processed, the blood oxygen saturation and pulse rate values ​​are accurately displayed on the screen. The stable line connection also effectively filters out environmental electromagnetic noise, avoiding waveform jitter and data drift, allowing patients with weak perfusion or high limb movement to obtain reliable readings.

 

Features


1. Compatible Model: Comen C60 Patient Monitor
2. Part Number: 36516
3. Compatible Technology: Masimo Original Pulse Oxygen Acquisition Protocol
4. Cable Material: Medical-grade TPU environmentally friendly insulating outer layer, internal multi-strand pure copper shielded wire core
5. Connector Structure: Device-side foolproof positioning plug, probe-side compatible with Masimo standard interface
6. Overall Length: Fits the C60 body wiring specifications, meeting standard bedside wiring needs
7. Protection Performance: Tensile resistance, bending resistance, electromagnetic interference protection, supports high-frequency wiping disinfection
8. Applicable Scenarios: Suitable for use with pulse oxygen monitoring for all age groups, including adults, children, and newborns.

 

Note

 

1. Handle the cable with care when assembling and disassembling the connector. Do not pull or twist the cable forcefully to prevent breakage of the internal shielding layer and wire cores.

 

2. For cleaning and maintenance, only use a soft medical cloth or disinfectant wipes to wipe the outer layer. Liquids must not seep into the connector gaps, and the entire cable must not be soaked for disinfection.

 

3. This connector cable is only compatible with the Comen C60 and the Masimo blood oxygenation solution. Using other models or non-compliant cables may cause data anomalies or even damage to the interface circuitry.

Kontaktdaten
China World Technology Medical Equipment Service Group

Ansprechpartner: Rita

Telefon: +8618279091952

Senden Sie Ihre Anfrage direkt an uns
China World Technology Medical Equipment Service Group
TianHe-Bezirk, Guangzhou, Guangdong
Telefon:86-198-5481-5217
Mobile Seite Datenschutz-Bestimmungen | CHINA Gut Qualität Benutzter Patientenmonitor Lieferant. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.